The BCJ162A project file describes a 162-square-metre smart mushroom-growing module identified in the body specification as model KS-JG162A. It combines an insulated enclosure, heating and cooling, fresh-air and supply-air systems, automated humidification, environmental sensing, remote control and seven-tier production racks.
Enclosure and overall design
The module uses a cold-store-style insulated foundation with an assembled polyurethane-panel enclosure. The five insulated faces are specified as 100 mm metal-faced polyurethane sandwich panels with 0.326 mm colour-coated steel skins on both sides. External dimensions are 20,200 mm long, 8,100 mm wide and 3,000 mm high.
| Item | Specification |
|---|---|
| Product model | KS-JG162A |
| External dimensions | 20,200 L × 8,100 W × 3,000 H mm |
| Cooling capacity | 21 kW |
| Heating capacity | 27 kW |
| CO2 concentration range | 0-15,000 ppm |
| Fresh-air volume | 970 m³/h |
| Supply-air volume | 3,600 m³/h |
| Humidity range | 60-95% RH |
| Electric-heating power | 10.8 kW |
| Power supply | 380 V / 50 Hz |
| Rated power | 18.8 kW |
| Refrigerant | R410A |
Environmental sensing and control
The temperature, humidity and carbon-dioxide transmitter is specified for probe operation from -40 to 80°C and 0-100% RH. The transmitter circuit-board environment is -40 to 60°C and 0-95% RH, non-condensing. Humidity accuracy is ±3% RH at 25°C; temperature accuracy is ±0.5°C at 25°C. Long-term stability is stated as 1% RH per year and 0.1°C per year. Carbon-dioxide measurement is 0-10,000 ppm with ±50 ppm accuracy and a 1-second refresh rate.
The KSZK-01 intelligent environmental controller includes an operator screen, one software package, a remote-control module and a high-definition camera for remote monitoring and control. Commissioning should verify sensor placement, alarm behaviour, actuator interlocks and data logging under a fully loaded crop.
Moving spray humidification system
The specified lift-and-lower spray system operates at 220 V and is designed to distribute moisture uniformly through the cabin. The source lists a humidification rate of 27.6 L/min per line and a target capability up to 95% RH.
| Category | Component | Specification | Quantity | Note |
|---|---|---|---|---|
| Equipment | Electric lifting unit | IP67, 8 m | 5 sets | Includes rope winder; main water line routed to unit |
| Equipment | Lift-spray control system | Integrated | 0 standalone units | Connects to module master control |
| Cable | 4 × 0.5 mm² cable | National standard | 125 m | Lifting-unit cable |
| Cable | 2 × 1 mm² cable | National standard | 125 m | Solenoid-valve control |
| Spray | PE flexible water hose | 32 mm | 15 m | – |
| Spray | PVC water pipe | 25 mm | 90 m | – |
| Spray | PVC tee | 25 mm | 300 | – |
| Spray | PVC 1/2-inch female threaded tee | Standard | 300 | – |
| Spray | PVC 1/2-inch female threaded elbow | Standard | 20 | – |
| Spray | Brass reducing bush | 1/2-inch male to 1/4-inch female | 300 | – |
| Spray | 3/4-inch solenoid valve | Brass base | 7 | Outlet valve |
| Spray | Fan nozzle | No. 1 | 300 | 600 mm nozzle spacing |
| Installation | Galvanised square tube | Hot-dip galvanised, 20 × 20 mm | 90 m | – |
| Installation | Cable ties | 4 × 200 mm | 10 packs | – |
| Installation | Electrical tape | Standard | 4 rolls | – |
| Installation | PVC conduit | 20 mm | 125 m | – |
| Installation | PTFE thread-seal tape | Standard | 60 rolls | – |
Fabric air-distribution system
The drawings show two longitudinal flexible fabric ducts serving the rack plan. The component schedule identifies two reducing fabric ducts, support wire ropes and outlet fixing accessories. Final duct diameter, perforation pattern, suspension spacing and fan duty must be reconciled with the 3,600 m³/h supply-air requirement and the fully loaded rack pressure drop.
Ozone sanitation system
| Item | Specification |
|---|---|
| Power supply | AC 220 V, 50 Hz |
| Ozone output | 100 g/h |
| Rated power | 1,500 W |
| Dimensions | 550 × 400 × 1,300 mm |
| Weight | 76 kg |
| Cabinet material | 304 stainless steel |
| Cooling fans | 3 × 38 W |
| Ozone concentration | 3-4 mg/L |
pH and moisture probes
The pHG-2091Pro pH/ORP instrument includes an internal A/D conversion module, two 4-20 mA outputs and RS485 communication. It supports Modbus RTU supervisory monitoring and recording.
| Item | Specification |
|---|---|
| Housing / protection | ABS plastic / IP65 |
| Power | 90-260 V AC, 50/60 Hz; 4 W |
| Measurement | pH / ORP |
| Outputs | Two 4-20 mA channels and RS485 |
| Relay rating | 5 A / 250 V AC; 5 A / 30 V DC |
| Temperature compensation | PT1000 / NTC10K |
| Size / weight | 98.2 × 98.2 × 128.3 mm / 0.9 kg |
| Communication | Modbus RTU |
| Measurement range | -2 to 16 pH; -2,000 to 2,000 mV; -30 to 130°C |
| Accuracy | ±1% FS and ±0.5°C |
| Compatible electrodes | pH8012, pH8012F, pH8010, pH8010F, ORP8083 |
The substrate-moisture probe measures volumetric relative water content from 0 to 100% (m³/m³). Supply is 12-24 V with selectable 0-2 V, 4-20 mA or RS485 output. Stated measurement accuracy is better than ±3% (m³/m³), interchangeability better than 3% and repeat error below 1%. It uses frequency-domain reflectometry at 100 MHz, responds in under one second and stabilises within one second.
Operating temperature is -30 to 70°C. The source defines 95% of the measurement influence within a cylinder 7 cm in diameter and 7 cm high around the centre probe. Probe length is 5.5 cm, diameter 3 mm, material stainless steel with anti-electrolysis treatment, and sealing is black flame-retardant resin. Standard shielded cable length is 3 m. Typical current is approximately 16 mA in low-power voltage mode and 23 mA in normal operation.
Racking and access door
| Item | Specification |
|---|---|
| Height | 2.1 m |
| Length | 20 m |
| Number of tiers | 7 |
| Upright spacing | 2 m |
| Upright section | 30 × 30 × 1.3 mm |
The access door is specified as the primary entrance with a clear width of 880 mm. Final engineering should verify personnel access, emergency egress, trolley clearance, drainage thresholds, cleanability and the relationship between rack ends and the door swing.